LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-SL192607

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminairePioneer - Spot Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux840 lmInput power7.0 W
Efficacy120.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC220~240V - 50/60Hz

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity2,161.3 cd
At angle0° VLuminous shapeCircular
Luminous size0 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

54010811621216190°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°78593.4%
0–60°840100.0%
0–90° (total)840100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m2161 luxØ0.6 m2 m540 luxØ1.3 m3 m240 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
2,161.346°3.0
2,159.847°2.1
2,153.648°1.5
2,141.049°1.0
2,121.150°0.7
2,093.151°0.5
2,056.652°0.3
2,011.453°0.0
1,957.654°0.0
1,895.355°0.0
10°1,825.056°0.0
11°1,747.457°0.0
12°1,663.258°0.0
13°1,573.459°0.0
14°1,479.260°0.0
15°1,381.561°0.0
16°1,281.762°0.0
17°1,181.063°0.0
18°1,080.664°0.0
19°981.765°0.0
20°885.266°0.0
21°792.367°0.0
22°703.868°0.0
23°620.369°0.0
24°542.370°0.0
25°470.471°0.0
26°404.772°0.0
27°345.273°0.0
28°292.174°0.0
29°245.075°0.0
30°203.776°0.0
31°167.977°0.0
32°137.178°0.0
33°111.079°0.0
34°89.080°0.0
35°70.881°0.0
36°55.782°0.0
37°43.483°0.0
38°33.684°0.0
39°25.785°0.0
40°19.486°0.0
41°14.687°0.0
42°10.888°0.0
43°8.089°0.0
44°5.890°0.0
45°4.2

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m54033766601.3 m
2.5 m346260921721.6 m
3.0 m240199983061.9 m
3.5 m1761549338112.3 m
4.0 m1351228443172.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².