LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-STR322120

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireWinchester - Street Lights, 155 degLamp / LEDIntegrated LED module
Luminous flux16,800 lmInput power120.0 W
Efficacy140.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B3-U0-G4
Beam angle (50% Imax)155.0°Field angle (10% Imax)179.4°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity3,737.9 cd
At angle0° VLuminous shapeCircular
Luminous size584 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

93418692803373890°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°3,11518.5%
0–60°10,63363.3%
0–90° (total)16,800100.0%

Flux emitted within each downward cone. 88% of the total falls inside the rated beam angle.

BUG rating B3-U0-G4

ZoneBack lmFront lm
Low 0–30°1,5571,557
Mid 30–60°3,7593,759
High 60–80°2,3252,325
Very high 80–90°758758
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m3738 luxØ9.0 m2 m934 luxØ18.0 m3 m415 luxØ27.1 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
3,737.946°3,323.0
3,737.947°3,293.5
3,737.948°3,262.7
3,737.849°3,230.6
3,737.850°3,197.3
3,737.651°3,162.7
3,737.452°3,126.9
3,737.253°3,089.7
3,736.754°3,051.4
3,736.255°3,011.8
10°3,735.456°2,971.0
11°3,734.557°2,928.9
12°3,733.358°2,885.7
13°3,731.959°2,841.4
14°3,730.260°2,796.0
15°3,728.261°2,749.4
16°3,725.862°2,701.8
17°3,723.063°2,653.2
18°3,719.864°2,603.7
19°3,716.265°2,553.2
20°3,712.166°2,501.9
21°3,707.467°2,449.8
22°3,702.268°2,396.9
23°3,696.569°2,343.3
24°3,690.070°2,289.1
25°3,683.071°2,234.3
26°3,675.272°2,179.0
27°3,666.773°2,123.2
28°3,657.474°2,067.1
29°3,647.475°2,010.7
30°3,636.576°1,954.1
31°3,624.777°1,897.4
32°3,612.078°1,840.5
33°3,598.479°1,783.7
34°3,583.880°1,727.0
35°3,568.281°1,670.4
36°3,551.682°1,614.0
37°3,533.983°1,558.0
38°3,515.184°1,502.4
39°3,495.285°1,447.2
40°3,474.286°1,392.5
41°3,452.087°1,338.5
42°3,428.788°1,285.1
43°3,404.189°1,232.5
44°3,378.390°0.0
45°3,351.3

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m93485165745329618.0 m
2.5 m59856347436626722.6 m
3.0 m41539835329223027.1 m
3.5 m30529627023419431.6 m
4.0 m23422821319016436.1 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².