LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-UL182103

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireShadow II - Floor Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux270 lmInput power3.0 W
Efficacy90.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B1-U0-G0
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
Voltage24V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity694.7 cd
At angle0° VLuminous shapeCircular
Luminous size113 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

17434752169590°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°25293.4%
0–60°270100.0%
0–90° (total)270100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

BUG rating B1-U0-G0

ZoneBack lmFront lm
Low 0–30°126126
Mid 30–60°99
High 60–80°00
Very high 80–90°00
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m695 luxØ0.6 m2 m174 luxØ1.3 m3 m77 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
694.746°1.0
694.247°0.7
692.248°0.5
688.249°0.3
681.850°0.2
672.851°0.2
661.152°0.1
646.553°0.0
629.254°0.0
609.255°0.0
10°586.656°0.0
11°561.757°0.0
12°534.658°0.0
13°505.759°0.0
14°475.460°0.0
15°444.161°0.0
16°412.062°0.0
17°379.663°0.0
18°347.364°0.0
19°315.565°0.0
20°284.566°0.0
21°254.767°0.0
22°226.268°0.0
23°199.469°0.0
24°174.370°0.0
25°151.271°0.0
26°130.172°0.0
27°111.073°0.0
28°93.974°0.0
29°78.775°0.0
30°65.576°0.0
31°54.077°0.0
32°44.178°0.0
33°35.779°0.0
34°28.680°0.0
35°22.781°0.0
36°17.982°0.0
37°14.083°0.0
38°10.884°0.0
39°8.285°0.0
40°6.286°0.0
41°4.787°0.0
42°3.588°0.0
43°2.689°0.0
44°1.990°0.0
45°1.3

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m17410821201.3 m
2.5 m1118330511.6 m
3.0 m776432921.9 m
3.5 m5750301242.3 m
4.0 m4339271452.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².