LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-MG10-06

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireCone - Magnetic Series, 110 degLamp / LEDIntegrated LED module
Luminous flux480 lmInput power6.0 W
Efficacy80.0 lm/WCCT
CRI90UGR<19
Beam angle (50% Imax)110.0°Field angle (10% Imax)157.4°
VoltageDC 48V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity168.8 cd
At angle0° VLuminous shapeCircular
Luminous size0 mm dia.Spacing/height (nominal)10.01

Luminous intensity (cd)

428412716990°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°13828.7%
0–60°39582.3%
0–90° (total)480100.0%

Flux emitted within each downward cone. 75% of the total falls inside the rated beam angle.

Illuminance cone

1 m169 luxØ2.9 m2 m42 luxØ5.7 m3 m19 luxØ8.6 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
168.846°115.6
168.847°112.4
168.848°109.0
168.849°105.6
168.850°102.2
168.851°98.7
168.852°95.2
168.753°91.6
168.754°88.0
168.655°84.4
10°168.556°80.8
11°168.357°77.2
12°168.158°73.7
13°167.959°70.1
14°167.760°66.6
15°167.461°63.2
16°167.062°59.8
17°166.663°56.4
18°166.264°53.1
19°165.665°50.0
20°165.066°46.9
21°164.467°43.8
22°163.668°40.9
23°162.869°38.1
24°161.970°35.4
25°160.971°32.8
26°159.872°30.4
27°158.673°28.0
28°157.374°25.8
29°155.975°23.7
30°154.476°21.7
31°152.877°19.8
32°151.178°18.0
33°149.379°16.4
34°147.380°14.9
35°145.381°13.5
36°143.182°12.2
37°140.983°10.9
38°138.584°9.8
39°136.085°8.8
40°133.486°7.9
41°130.687°7.1
42°127.888°6.3
43°124.989°5.6
44°121.990°0.0
45°118.8

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m42382818115.7 m
2.5 m27252115107.1 m
3.0 m1918161398.6 m
3.5 m14131210810.0 m
4.0 m1110108711.4 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².