LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-STL358001

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireBam - Wall Recessed, 24 degLamp / LEDIntegrated LED module
Luminous flux120 lmInput power1.0 W
Efficacy120.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B0-U0-G0
Beam angle (50% Imax)24.0°Field angle (10% Imax)43.3°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity548.8 cd
At angle0° VLuminous shapeCircular
Luminous size80 mm dia.Spacing/height (nominal)0.79

Luminous intensity (cd)

13727441254990°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°10688.7%
0–60°11797.4%
0–90° (total)120100.0%

Flux emitted within each downward cone. 46% of the total falls inside the rated beam angle.

BUG rating B0-U0-G0

ZoneBack lmFront lm
Low 0–30°5353
Mid 30–60°55
High 60–80°11
Very high 80–90°00
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m549 luxØ0.4 m2 m137 luxØ0.9 m3 m61 luxØ1.3 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
548.846°4.2
546.747°4.1
540.048°3.9
528.449°3.7
512.150°3.6
491.351°3.4
466.552°3.3
438.553°3.1
407.854°3.0
375.355°2.8
10°341.756°2.7
11°307.957°2.6
12°274.458°2.4
13°242.059°2.3
14°211.260°2.2
15°182.561°2.1
16°156.062°2.0
17°132.263°1.9
18°110.964°1.8
19°92.365°1.7
20°76.266°1.6
21°62.567°1.5
22°51.168°1.4
23°41.669°1.3
24°33.870°1.2
25°27.571°1.2
26°22.672°1.1
27°18.673°1.0
28°15.674°1.0
29°13.275°0.9
30°11.476°0.8
31°10.077°0.8
32°8.978°0.7
33°8.179°0.7
34°7.480°0.6
35°6.981°0.6
36°6.582°0.5
37°6.283°0.5
38°5.984°0.5
39°5.685°0.4
40°5.486°0.4
41°5.287°0.4
42°5.088°0.3
43°4.889°0.3
44°4.690°0.0
45°4.4

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m137484100.9 m
2.5 m88457101.1 m
3.0 m613810201.3 m
3.5 m453211311.5 m
4.0 m342712411.7 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².