Photometric Data Sheet
| Luminaire | Rock - Flood & Spike Lights, 36 deg | Lamp / LED | Integrated LED module |
|---|---|---|---|
| Luminous flux | 14,500 lm | Input power | 100.0 W |
| Efficacy | 145.0 lm/W | CCT | |
| CRI | >90 | BUG rating (TM-15-11) | B4-U0-G0 |
| Beam angle (50% Imax) | 36.0° | Field angle (10% Imax) | 59.4° |
| Voltage | AC220~240V |
| Distribution | Direct, rotationally symmetric | Maximum intensity | 37,307.3 cd |
|---|---|---|---|
| At angle | 0° V | Luminous shape | Circular |
| Luminous size | 332 mm dia. | Spacing/height (nominal) | 1.14 |
Polar distribution, rotationally symmetric. 0° is straight down.
| Zone | Lumens | % of total |
|---|---|---|
| 0–30° | 13,544 | 93.4% |
| 0–60° | 14,500 | 100.0% |
| 0–90° (total) | 14,500 | 100.0% |
Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.
| Zone | Back lm | Front lm |
|---|---|---|
| Low 0–30° | 6,772 | 6,772 |
| Mid 30–60° | 478 | 478 |
| High 60–80° | 0 | 0 |
| Very high 80–90° | 0 | 0 |
| Uplight 90–100° / 100–180° | 0 / 0 | |
Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.
Centre-beam illuminance and beam diameter on a surface directly below.
| γ | cd | γ | cd |
|---|---|---|---|
| 0° | 37,307.3 | 46° | 51.3 |
| 1° | 37,282.2 | 47° | 36.2 |
| 2° | 37,175.0 | 48° | 25.3 |
| 3° | 36,958.1 | 49° | 17.5 |
| 4° | 36,614.1 | 50° | 11.9 |
| 5° | 36,130.9 | 51° | 8.1 |
| 6° | 35,501.0 | 52° | 5.4 |
| 7° | 34,720.9 | 53° | 0.0 |
| 8° | 33,791.2 | 54° | 0.0 |
| 9° | 32,715.9 | 55° | 0.0 |
| 10° | 31,502.9 | 56° | 0.0 |
| 11° | 30,162.9 | 57° | 0.0 |
| 12° | 28,710.0 | 58° | 0.0 |
| 13° | 27,160.6 | 59° | 0.0 |
| 14° | 25,533.2 | 60° | 0.0 |
| 15° | 23,847.8 | 61° | 0.0 |
| 16° | 22,125.3 | 62° | 0.0 |
| 17° | 20,386.9 | 63° | 0.0 |
| 18° | 18,653.6 | 64° | 0.0 |
| 19° | 16,945.5 | 65° | 0.0 |
| 20° | 15,281.1 | 66° | 0.0 |
| 21° | 13,677.3 | 67° | 0.0 |
| 22° | 12,148.5 | 68° | 0.0 |
| 23° | 10,706.9 | 69° | 0.0 |
| 24° | 9,361.9 | 70° | 0.0 |
| 25° | 8,120.1 | 71° | 0.0 |
| 26° | 6,985.5 | 72° | 0.0 |
| 27° | 5,959.6 | 73° | 0.0 |
| 28° | 5,041.5 | 74° | 0.0 |
| 29° | 4,228.5 | 75° | 0.0 |
| 30° | 3,515.9 | 76° | 0.0 |
| 31° | 2,897.7 | 77° | 0.0 |
| 32° | 2,366.9 | 78° | 0.0 |
| 33° | 1,916.0 | 79° | 0.0 |
| 34° | 1,536.8 | 80° | 0.0 |
| 35° | 1,221.3 | 81° | 0.0 |
| 36° | 961.5 | 82° | 0.0 |
| 37° | 749.8 | 83° | 0.0 |
| 38° | 579.2 | 84° | 0.0 |
| 39° | 443.0 | 85° | 0.0 |
| 40° | 335.6 | 86° | 0.0 |
| 41° | 251.7 | 87° | 0.0 |
| 42° | 186.9 | 88° | 0.0 |
| 43° | 137.4 | 89° | 0.0 |
| 44° | 100.0 | 90° | 0.0 |
| 45° | 72.0 |
Candela at each vertical angle, C0-C180 plane.
| Mounting height | centre | 0.5 m | 1.0 m | 1.5 m | 2.0 m | Beam Ø |
|---|---|---|---|---|---|---|
| 2.0 m | 9,327 | 5,814 | 1,146 | 100 | 6 | 1.3 m |
| 2.5 m | 5,969 | 4,482 | 1,595 | 295 | 37 | 1.6 m |
| 3.0 m | 4,145 | 3,429 | 1,699 | 509 | 106 | 1.9 m |
| 3.5 m | 3,045 | 2,665 | 1,612 | 662 | 198 | 2.3 m |
| 4.0 m | 2,332 | 2,113 | 1,454 | 738 | 286 | 2.6 m |
Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².