LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-FL3085100

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireLuminex - Flood & Spike Lights, 30 degLamp / LEDIntegrated LED module
Luminous flux12,000 lmInput power100.0 W
Efficacy120.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B4-U0-G0
Beam angle (50% Imax)30.0°Field angle (10% Imax)50.2°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity42,632.7 cd
At angle0° VLuminous shapeCircular
Luminous size386 mm dia.Spacing/height (nominal)0.94

Luminous intensity (cd)

1065821316319744263390°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°11,51095.9%
0–60°11,93899.5%
0–90° (total)12,000100.0%

Flux emitted within each downward cone. 56% of the total falls inside the rated beam angle.

BUG rating B4-U0-G0

ZoneBack lmFront lm
Low 0–30°5,7555,755
Mid 30–60°214214
High 60–80°2626
Very high 80–90°55
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m42633 luxØ0.5 m2 m10658 luxØ1.1 m3 m4737 luxØ1.6 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
42,632.746°86.9
42,581.447°82.5
42,372.648°78.5
41,962.149°74.9
41,324.950°71.5
40,447.751°68.3
39,326.652°65.2
37,966.353°62.2
36,380.054°59.4
34,588.055°56.6
10°32,617.256°53.9
11°30,499.857°51.3
12°28,272.058°48.7
13°25,972.559°46.3
14°23,640.960°44.0
15°21,316.361°41.7
16°19,035.862°39.5
17°16,832.863°37.4
18°14,736.764°35.4
19°12,771.365°33.4
20°10,955.066°31.5
21°9,300.367°29.8
22°7,813.868°28.0
23°6,496.969°26.4
24°5,346.370°24.9
25°4,354.971°23.4
26°3,512.372°21.9
27°2,805.873°20.6
28°2,221.474°19.3
29°1,744.675°18.1
30°1,360.776°16.9
31°1,055.877°15.8
32°816.778°14.8
33°631.679°13.8
34°490.180°12.9
35°383.181°12.0
36°303.182°11.2
37°243.983°10.4
38°200.484°9.7
39°168.585°9.0
40°145.286°8.3
41°128.087°7.7
42°115.388°7.1
43°105.689°6.6
44°98.090°0.0
45°92.0

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m10,6585,3775573281.1 m
2.5 m6,8214,4971,038108141.3 m
3.0 m4,7373,5911,317248341.6 m
3.5 m3,4802,8631,390397781.9 m
4.0 m2,6652,3061,3445151392.1 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².