LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-FL3072400

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireVilux - Flood & Spike Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux60,000 lmInput power400.0 W
Efficacy150.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B4-U0-G0
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity154,375.0 cd
At angle0° VLuminous shapeCircular
Luminous size586 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

385947718811578115437590°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°56,04593.4%
0–60°60,000100.0%
0–90° (total)60,000100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

BUG rating B4-U0-G0

ZoneBack lmFront lm
Low 0–30°28,02228,022
Mid 30–60°1,9781,978
High 60–80°00
Very high 80–90°00
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m154375 luxØ0.6 m2 m38594 luxØ1.3 m3 m17153 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
154,375.046°212.4
154,271.147°149.8
153,827.548°104.6
152,930.349°72.2
151,506.750°49.3
149,507.251°33.4
146,900.652°22.3
143,672.853°0.0
139,825.654°0.0
135,376.355°0.0
10°130,356.656°0.0
11°124,812.157°0.0
12°118,800.158°0.0
13°112,388.859°0.0
14°105,654.760°0.0
15°98,680.561°0.0
16°91,552.962°0.0
17°84,359.763°0.0
18°77,187.564°0.0
19°70,119.365°0.0
20°63,232.166°0.0
21°56,595.567°0.0
22°50,269.768°0.0
23°44,304.569°0.0
24°38,738.870°0.0
25°33,600.371°0.0
26°28,905.472°0.0
27°24,660.373°0.0
28°20,861.574°0.0
29°17,497.275°0.0
30°14,548.476°0.0
31°11,990.377°0.0
32°9,794.178°0.0
33°7,928.279°0.0
34°6,359.280°0.0
35°5,053.681°0.0
36°3,978.682°0.0
37°3,102.783°0.0
38°2,396.584°0.0
39°1,833.385°0.0
40°1,388.786°0.0
41°1,041.687°0.0
42°773.588°0.0
43°568.689°0.0
44°413.890°0.0
45°298.0

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m38,59424,0604,742412261.3 m
2.5 m24,70018,5486,5991,2191541.6 m
3.0 m17,15314,1897,0312,1074381.9 m
3.5 m12,60211,0286,6722,7388182.3 m
4.0 m9,6488,7446,0153,0551,1852.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².