LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-ODL349012

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireBulk - Wall Surface, 120 degLamp / LEDIntegrated LED module
Luminous flux1,440 lmInput power12.0 W
Efficacy120.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B1-U0-G1
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity441.4 cd
At angle0° VLuminous shapeCircular
Luminous size275 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

11022133144190°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°36325.2%
0–60°1,10776.9%
0–90° (total)1,440100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

BUG rating B1-U0-G1

ZoneBack lmFront lm
Low 0–30°181181
Mid 30–60°372372
High 60–80°142142
Very high 80–90°2525
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m441 luxØ3.5 m2 m110 luxØ6.9 m3 m49 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
441.446°333.2
441.447°326.2
441.448°319.0
441.349°311.5
441.350°303.9
441.351°296.1
441.252°288.2
441.153°280.1
441.054°271.8
440.955°263.5
10°440.756°255.1
11°440.457°246.5
12°440.158°238.0
13°439.759°229.3
14°439.260°220.7
15°438.661°212.0
16°437.962°203.4
17°437.163°194.8
18°436.364°186.2
19°435.265°177.7
20°434.166°169.3
21°432.867°161.0
22°431.368°152.9
23°429.769°144.9
24°427.970°137.0
25°426.071°129.3
26°423.872°121.8
27°421.573°114.6
28°419.074°107.5
29°416.275°100.6
30°413.276°94.0
31°410.177°87.7
32°406.678°81.6
33°403.079°75.7
34°399.180°70.1
35°395.081°64.8
36°390.682°59.7
37°385.983°54.9
38°381.184°50.4
39°375.985°46.1
40°370.686°42.1
41°364.987°38.4
42°359.188°34.9
43°352.989°31.6
44°346.690°0.0
45°340.0

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m1101007649306.9 m
2.5 m71665541298.7 m
3.0 m494741342610.4 m
3.5 m363532272212.1 m
4.0 m282725221913.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².