LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-ODL371706

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireAlbion - Ceiling Surface Lights, 120 degLamp / LEDIntegrated LED module
Luminous flux430 lmInput power6.0 W
Efficacy71.7 lm/WCCT
CRI>90BUG rating (TM-15-11)B0-U0-G0
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity131.8 cd
At angle0° VLuminous shapeCircular
Luminous size0 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

33669913290°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°10825.2%
0–60°33076.9%
0–90° (total)430100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

BUG rating B0-U0-G0

ZoneBack lmFront lm
Low 0–30°5454
Mid 30–60°111111
High 60–80°4242
Very high 80–90°77
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m132 luxØ3.5 m2 m33 luxØ6.9 m3 m15 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
131.846°99.5
131.847°97.4
131.848°95.2
131.849°93.0
131.850°90.8
131.851°88.4
131.852°86.1
131.753°83.6
131.754°81.2
131.655°78.7
10°131.656°76.2
11°131.557°73.6
12°131.458°71.1
13°131.359°68.5
14°131.160°65.9
15°131.061°63.3
16°130.862°60.7
17°130.563°58.2
18°130.364°55.6
19°130.065°53.1
20°129.666°50.6
21°129.267°48.1
22°128.868°45.7
23°128.369°43.3
24°127.870°40.9
25°127.271°38.6
26°126.672°36.4
27°125.973°34.2
28°125.174°32.1
29°124.375°30.1
30°123.476°28.1
31°122.477°26.2
32°121.478°24.4
33°120.379°22.6
34°119.280°20.9
35°117.981°19.3
36°116.682°17.8
37°115.283°16.4
38°113.884°15.1
39°112.385°13.8
40°110.786°12.6
41°109.087°11.5
42°107.288°10.4
43°105.489°9.4
44°103.590°0.0
45°101.5

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m3330231596.9 m
2.5 m2120171298.7 m
3.0 m15141210810.4 m
3.5 m111098712.1 m
4.0 m8877613.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².