LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-IL295050

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireFact - Industrial Lights, 120 degLamp / LEDIntegrated LED module
Luminous flux7,500 lmInput power50.0 W
Efficacy150.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B2-U0-G2
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity2,298.7 cd
At angle0° VLuminous shapeCircular
Luminous size1,250 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

57511491724229990°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,88925.2%
0–60°5,76476.9%
0–90° (total)7,500100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

BUG rating B2-U0-G2

ZoneBack lmFront lm
Low 0–30°945945
Mid 30–60°1,9371,937
High 60–80°738738
Very high 80–90°130130
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m2299 luxØ3.5 m2 m575 luxØ6.9 m3 m255 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
2,298.746°1,735.5
2,298.747°1,698.9
2,298.748°1,661.2
2,298.749°1,622.5
2,298.650°1,582.8
2,298.451°1,542.3
2,298.152°1,500.9
2,297.653°1,458.7
2,297.054°1,415.9
2,296.255°1,372.4
10°2,295.156°1,328.4
11°2,293.757°1,284.1
12°2,292.058°1,239.4
13°2,289.959°1,194.4
14°2,287.460°1,149.4
15°2,284.461°1,104.3
16°2,280.962°1,059.2
17°2,276.863°1,014.4
18°2,272.264°969.8
19°2,266.865°925.6
20°2,260.866°881.9
21°2,254.167°838.7
22°2,246.568°796.2
23°2,238.269°754.5
24°2,228.970°713.6
25°2,218.771°673.6
26°2,207.572°634.6
27°2,195.373°596.6
28°2,182.174°559.8
29°2,167.875°524.2
30°2,152.376°489.8
31°2,135.777°456.6
32°2,117.978°424.8
33°2,098.979°394.3
34°2,078.680°365.2
35°2,057.081°337.5
36°2,034.282°311.1
37°2,010.183°286.1
38°1,984.784°262.5
39°1,958.085°240.3
40°1,930.086°219.4
41°1,900.787°199.8
42°1,870.188°181.5
43°1,838.389°164.5
44°1,805.290°0.0
45°1,770.9

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m5755223942581576.9 m
2.5 m3683462882161508.7 m
3.0 m25524521517513310.4 m
3.5 m18818216614211512.1 m
4.0 m1441401311169813.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².