LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-IL2940150

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireANDREW Ill - Industrial Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux18,000 lmInput power150.0 W
Efficacy120.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B4-U0-G0
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity46,312.5 cd
At angle0° VLuminous shapeCircular
Luminous size286 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

1157823156347344631390°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°16,81393.4%
0–60°18,000100.0%
0–90° (total)18,000100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

BUG rating B4-U0-G0

ZoneBack lmFront lm
Low 0–30°8,4078,407
Mid 30–60°593593
High 60–80°00
Very high 80–90°00
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m46313 luxØ0.6 m2 m11578 luxØ1.3 m3 m5146 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
46,312.546°63.7
46,281.347°45.0
46,148.248°31.4
45,879.149°21.7
45,452.050°14.8
44,852.251°10.0
44,070.252°6.7
43,101.853°0.0
41,947.754°0.0
40,612.955°0.0
10°39,107.056°0.0
11°37,443.657°0.0
12°35,640.058°0.0
13°33,716.659°0.0
14°31,696.460°0.0
15°29,604.261°0.0
16°27,465.962°0.0
17°25,307.963°0.0
18°23,156.364°0.0
19°21,035.865°0.0
20°18,969.666°0.0
21°16,978.767°0.0
22°15,080.968°0.0
23°13,291.469°0.0
24°11,621.770°0.0
25°10,080.171°0.0
26°8,671.672°0.0
27°7,398.173°0.0
28°6,258.574°0.0
29°5,249.275°0.0
30°4,364.576°0.0
31°3,597.177°0.0
32°2,938.278°0.0
33°2,378.479°0.0
34°1,907.880°0.0
35°1,516.181°0.0
36°1,193.682°0.0
37°930.883°0.0
38°719.084°0.0
39°550.085°0.0
40°416.686°0.0
41°312.587°0.0
42°232.088°0.0
43°170.689°0.0
44°124.190°0.0
45°89.4

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m11,5787,2181,42212481.3 m
2.5 m7,4105,5641,980366461.6 m
3.0 m5,1464,2572,1096321311.9 m
3.5 m3,7813,3082,0028222452.3 m
4.0 m2,8952,6231,8049163562.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².