LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-ML2206

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireElegant - Wall Surface, 36 degLamp / LEDIntegrated LED module
Luminous flux660 lmInput power6.0 W
Efficacy110.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity1,698.1 cd
At angle0° VLuminous shapeCircular
Luminous size440 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

4258491274169890°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°61693.4%
0–60°660100.0%
0–90° (total)660100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m1698 luxØ0.6 m2 m425 luxØ1.3 m3 m189 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
1,698.146°2.3
1,697.047°1.6
1,692.148°1.2
1,682.249°0.8
1,666.650°0.5
1,644.651°0.4
1,615.952°0.2
1,580.453°0.0
1,538.154°0.0
1,489.155°0.0
10°1,433.956°0.0
11°1,372.957°0.0
12°1,306.858°0.0
13°1,236.359°0.0
14°1,162.260°0.0
15°1,085.561°0.0
16°1,007.162°0.0
17°928.063°0.0
18°849.164°0.0
19°771.365°0.0
20°695.666°0.0
21°622.667°0.0
22°553.068°0.0
23°487.369°0.0
24°426.170°0.0
25°369.671°0.0
26°318.072°0.0
27°271.373°0.0
28°229.574°0.0
29°192.575°0.0
30°160.076°0.0
31°131.977°0.0
32°107.778°0.0
33°87.279°0.0
34°70.080°0.0
35°55.681°0.0
36°43.882°0.0
37°34.183°0.0
38°26.484°0.0
39°20.285°0.0
40°15.386°0.0
41°11.587°0.0
42°8.588°0.0
43°6.389°0.0
44°4.690°0.0
45°3.3

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m42526552501.3 m
2.5 m272204731321.6 m
3.0 m189156772351.9 m
3.5 m139121733092.3 m
4.0 m106966634132.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².