LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-PNL211236

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireFlatty - Panel Lights, 120 degLamp / LEDIntegrated LED module
Luminous flux4,320 lmInput power36.0 W
Efficacy120.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity1,324.1 cd
At angle0° VLuminous shapeCircular
Luminous size595 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

331662993132490°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,08825.2%
0–60°3,32076.9%
0–90° (total)4,320100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

Illuminance cone

1 m1324 luxØ3.5 m2 m331 luxØ6.9 m3 m147 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
1,324.146°999.6
1,324.147°978.5
1,324.148°956.9
1,324.049°934.6
1,324.050°911.7
1,323.951°888.4
1,323.752°864.5
1,323.453°840.2
1,323.154°815.5
1,322.655°790.5
10°1,322.056°765.2
11°1,321.257°739.6
12°1,320.258°713.9
13°1,319.059°688.0
14°1,317.560°662.0
15°1,315.861°636.1
16°1,313.862°610.1
17°1,311.463°584.3
18°1,308.864°558.6
19°1,305.765°533.2
20°1,302.266°508.0
21°1,298.467°483.1
22°1,294.068°458.6
23°1,289.269°434.6
24°1,283.870°411.0
25°1,278.071°388.0
26°1,271.572°365.5
27°1,264.573°343.7
28°1,256.974°322.5
29°1,248.675°301.9
30°1,239.776°282.1
31°1,230.277°263.0
32°1,219.978°244.7
33°1,208.979°227.1
34°1,197.380°210.4
35°1,184.981°194.4
36°1,171.782°179.2
37°1,157.883°164.8
38°1,143.284°151.2
39°1,127.885°138.4
40°1,111.786°126.4
41°1,094.887°115.1
42°1,077.288°104.6
43°1,058.889°94.8
44°1,039.890°0.0
45°1,020.0

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m331301227148906.9 m
2.5 m212199166124868.7 m
3.0 m1471411241017710.4 m
3.5 m10810595826612.1 m
4.0 m838175675713.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².