LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-PNL212038

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireBrighty - Panel Lights, 120 degLamp / LEDIntegrated LED module
Luminous flux4,560 lmInput power36.0 W
Efficacy126.7 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity1,397.6 cd
At angle0° VLuminous shapeCircular
Luminous size595 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

3496991048139890°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,14925.2%
0–60°3,50476.9%
0–90° (total)4,560100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

Illuminance cone

1 m1398 luxØ3.5 m2 m349 luxØ6.9 m3 m155 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
1,397.646°1,055.2
1,397.647°1,032.9
1,397.648°1,010.0
1,397.649°986.5
1,397.550°962.4
1,397.451°937.7
1,397.252°912.5
1,397.053°886.9
1,396.654°860.8
1,396.155°834.4
10°1,395.456°807.7
11°1,394.657°780.7
12°1,393.558°753.5
13°1,392.259°726.2
14°1,390.760°698.8
15°1,388.961°671.4
16°1,386.862°644.0
17°1,384.363°616.8
18°1,381.564°589.7
19°1,378.265°562.8
20°1,374.666°536.2
21°1,370.567°510.0
22°1,365.968°484.1
23°1,360.869°458.7
24°1,355.270°433.9
25°1,349.071°409.5
26°1,342.272°385.8
27°1,334.873°362.8
28°1,326.774°340.4
29°1,318.075°318.7
30°1,308.676°297.8
31°1,298.577°277.6
32°1,287.778°258.3
33°1,276.179°239.8
34°1,263.880°222.0
35°1,250.781°205.2
36°1,236.882°189.2
37°1,222.183°174.0
38°1,206.784°159.6
39°1,190.585°146.1
40°1,173.486°133.4
41°1,155.687°121.5
42°1,137.088°110.4
43°1,117.789°100.0
44°1,097.690°0.0
45°1,076.7

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m349317239157956.9 m
2.5 m224210175131918.7 m
3.0 m1551491311068110.4 m
3.5 m114111101867012.1 m
4.0 m878579706013.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².