LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-DL178220

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireCama - Down Lights, 38 degLamp / LEDIntegrated LED module
Luminous flux2,400 lmInput power20.0 W
Efficacy120.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)38.0°Field angle (10% Imax)62.7°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity5,553.1 cd
At angle0° VLuminous shapeCircular
Luminous size165 mm dia.Spacing/height (nominal)1.22

Luminous intensity (cd)

138827774165555390°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°2,18691.1%
0–60°2,400100.0%
0–90° (total)2,400100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m5553 luxØ0.7 m2 m1388 luxØ1.4 m3 m617 luxØ2.1 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
5,553.146°17.0
5,549.947°12.5
5,535.848°9.1
5,507.549°6.6
5,462.450°4.7
5,399.151°3.4
5,316.352°2.4
5,213.653°1.6
5,090.754°1.1
4,948.255°0.8
10°4,786.756°0.0
11°4,607.457°0.0
12°4,411.958°0.0
13°4,202.159°0.0
14°3,980.160°0.0
15°3,748.461°0.0
16°3,509.562°0.0
17°3,266.163°0.0
18°3,020.964°0.0
19°2,776.665°0.0
20°2,535.666°0.0
21°2,300.367°0.0
22°2,072.868°0.0
23°1,855.269°0.0
24°1,648.870°0.0
25°1,455.171°0.0
26°1,274.972°0.0
27°1,108.973°0.0
28°957.474°0.0
29°820.475°0.0
30°697.676°0.0
31°588.677°0.0
32°492.878°0.0
33°409.379°0.0
34°337.280°0.0
35°275.681°0.0
36°223.482°0.0
37°179.683°0.0
38°143.184°0.0
39°113.185°0.0
40°88.686°0.0
41°68.887°0.0
42°53.088°0.0
43°40.589°0.0
44°30.690°0.0
45°22.9

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m1,3889072112421.4 m
2.5 m8896862716091.7 m
3.0 m61752027794232.1 m
3.5 m453402256115392.4 m
4.0 m347317227123532.8 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².