LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-DL2038326

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireSpoty IV - Down Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux1,320 lmInput power12.0 W
Efficacy110.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC 100~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity3,396.3 cd
At angle0° VLuminous shapeCircular
Luminous size220 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

84916982547339690°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,23393.4%
0–60°1,320100.0%
0–90° (total)1,320100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m3396 luxØ0.6 m2 m849 luxØ1.3 m3 m377 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
3,396.346°4.7
3,394.047°3.3
3,384.248°2.3
3,364.549°1.6
3,333.150°1.1
3,289.251°0.7
3,231.852°0.5
3,160.853°0.0
3,076.254°0.0
2,978.355°0.0
10°2,867.856°0.0
11°2,745.957°0.0
12°2,613.658°0.0
13°2,472.659°0.0
14°2,324.460°0.0
15°2,171.061°0.0
16°2,014.262°0.0
17°1,855.963°0.0
18°1,698.164°0.0
19°1,542.665°0.0
20°1,391.166°0.0
21°1,245.167°0.0
22°1,105.968°0.0
23°974.769°0.0
24°852.370°0.0
25°739.271°0.0
26°635.972°0.0
27°542.573°0.0
28°459.074°0.0
29°384.975°0.0
30°320.176°0.0
31°263.877°0.0
32°215.578°0.0
33°174.479°0.0
34°139.980°0.0
35°111.281°0.0
36°87.582°0.0
37°68.383°0.0
38°52.784°0.0
39°40.385°0.0
40°30.686°0.0
41°22.987°0.0
42°17.088°0.0
43°12.589°0.0
44°9.190°0.0
45°6.6

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m849529104911.3 m
2.5 m5434081452731.6 m
3.0 m37731215546101.9 m
3.5 m27724314760182.3 m
4.0 m21219213267262.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².