LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-SL184309

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireSHIRE - Spot Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux675 lmInput power9.0 W
Efficacy75.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity1,736.7 cd
At angle0° VLuminous shapeCircular
Luminous size85 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

4348681303173790°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°63193.4%
0–60°675100.0%
0–90° (total)675100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m1737 luxØ0.6 m2 m434 luxØ1.3 m3 m193 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
1,736.746°2.4
1,735.647°1.7
1,730.648°1.2
1,720.549°0.8
1,704.550°0.6
1,682.051°0.4
1,652.652°0.3
1,616.353°0.0
1,573.054°0.0
1,523.055°0.0
10°1,466.556°0.0
11°1,404.157°0.0
12°1,336.558°0.0
13°1,264.459°0.0
14°1,188.660°0.0
15°1,110.261°0.0
16°1,030.062°0.0
17°949.063°0.0
18°868.464°0.0
19°788.865°0.0
20°711.466°0.0
21°636.767°0.0
22°565.568°0.0
23°498.469°0.0
24°435.870°0.0
25°378.071°0.0
26°325.272°0.0
27°277.473°0.0
28°234.774°0.0
29°196.875°0.0
30°163.776°0.0
31°134.977°0.0
32°110.278°0.0
33°89.279°0.0
34°71.580°0.0
35°56.981°0.0
36°44.882°0.0
37°34.983°0.0
38°27.084°0.0
39°20.685°0.0
40°15.686°0.0
41°11.787°0.0
42°8.788°0.0
43°6.489°0.0
44°4.790°0.0
45°3.4

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m43427153501.3 m
2.5 m278209741421.6 m
3.0 m193160792451.9 m
3.5 m142124753192.3 m
4.0 m109986834132.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².