LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-UL652025

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireBeta - Floor Lights, 30 degLamp / LEDIntegrated LED module
Luminous flux3,000 lmInput power25.0 W
Efficacy120.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B3-U0-G0
Beam angle (50% Imax)30.0°Field angle (10% Imax)50.2°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity10,658.2 cd
At angle0° VLuminous shapeCircular
Luminous size260 mm dia.Spacing/height (nominal)0.94

Luminous intensity (cd)

2665532979941065890°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°2,87895.9%
0–60°2,98499.5%
0–90° (total)3,000100.0%

Flux emitted within each downward cone. 56% of the total falls inside the rated beam angle.

BUG rating B3-U0-G0

ZoneBack lmFront lm
Low 0–30°1,4391,439
Mid 30–60°5353
High 60–80°77
Very high 80–90°11
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m10658 luxØ0.5 m2 m2665 luxØ1.1 m3 m1184 luxØ1.6 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
10,658.246°21.7
10,645.447°20.6
10,593.148°19.6
10,490.549°18.7
10,331.250°17.9
10,111.951°17.1
9,831.652°16.3
9,491.653°15.6
9,095.054°14.8
8,647.055°14.1
10°8,154.356°13.5
11°7,625.057°12.8
12°7,068.058°12.2
13°6,493.159°11.6
14°5,910.260°11.0
15°5,329.161°10.4
16°4,758.962°9.9
17°4,208.263°9.3
18°3,684.264°8.8
19°3,192.865°8.4
20°2,738.866°7.9
21°2,325.167°7.4
22°1,953.468°7.0
23°1,624.269°6.6
24°1,336.670°6.2
25°1,088.771°5.8
26°878.172°5.5
27°701.473°5.1
28°555.474°4.8
29°436.275°4.5
30°340.276°4.2
31°263.977°4.0
32°204.278°3.7
33°157.979°3.5
34°122.580°3.2
35°95.881°3.0
36°75.882°2.8
37°61.083°2.6
38°50.184°2.4
39°42.185°2.2
40°36.386°2.1
41°32.087°1.9
42°28.888°1.8
43°26.489°1.7
44°24.590°0.0
45°23.0

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m2,6651,344139821.1 m
2.5 m1,7051,1242602731.3 m
3.0 m1,1848983296291.6 m
3.5 m87071634899191.9 m
4.0 m666577336129352.1 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².