LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-MG09-05

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireDroplet - Magnetic Series, 110 degLamp / LEDIntegrated LED module
Luminous flux325 lmInput power5.0 W
Efficacy65.0 lm/WCCT
CRI90UGR<19
Beam angle (50% Imax)110.0°Field angle (10% Imax)157.4°
VoltageDC 48V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity114.3 cd
At angle0° VLuminous shapeCircular
Luminous size0 mm dia.Spacing/height (nominal)10.01

Luminous intensity (cd)

29578611490°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°9328.7%
0–60°26782.3%
0–90° (total)325100.0%

Flux emitted within each downward cone. 75% of the total falls inside the rated beam angle.

Illuminance cone

1 m114 luxØ2.9 m2 m29 luxØ5.7 m3 m13 luxØ8.6 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
114.346°78.3
114.347°76.1
114.348°73.8
114.349°71.5
114.350°69.2
114.351°66.8
114.352°64.4
114.253°62.0
114.254°59.6
114.155°57.2
10°114.156°54.7
11°114.057°52.3
12°113.858°49.9
13°113.759°47.5
14°113.560°45.1
15°113.361°42.8
16°113.162°40.5
17°112.863°38.2
18°112.564°36.0
19°112.265°33.8
20°111.766°31.7
21°111.367°29.7
22°110.868°27.7
23°110.269°25.8
24°109.670°24.0
25°108.971°22.2
26°108.272°20.6
27°107.473°19.0
28°106.574°17.5
29°105.675°16.0
30°104.676°14.7
31°103.577°13.4
32°102.378°12.2
33°101.179°11.1
34°99.880°10.1
35°98.481°9.1
36°96.982°8.2
37°95.483°7.4
38°93.784°6.7
39°92.185°6.0
40°90.386°5.4
41°88.587°4.8
42°86.588°4.3
43°84.689°3.8
44°82.590°0.0
45°80.4

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m2926191275.7 m
2.5 m1817141077.1 m
3.0 m131211968.6 m
3.5 m9987610.0 m
4.0 m7766511.4 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².