LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-MG04-18

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireHoney - Magnetic Series, 38 degLamp / LEDIntegrated LED module
Luminous flux1,530 lmInput power18.0 W
Efficacy85.0 lm/WCCT
CRI90UGR<19
Beam angle (50% Imax)38.0°Field angle (10% Imax)62.7°
VoltageDC 48V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity3,540.1 cd
At angle0° VLuminous shapeCircular
Luminous size0 mm dia.Spacing/height (nominal)1.22

Luminous intensity (cd)

88517702655354090°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,39391.1%
0–60°1,530100.0%
0–90° (total)1,530100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m3540 luxØ0.7 m2 m885 luxØ1.4 m3 m393 luxØ2.1 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
3,540.146°10.9
3,538.047°8.0
3,529.148°5.8
3,511.049°4.2
3,482.350°3.0
3,441.951°2.1
3,389.152°1.5
3,323.653°1.0
3,245.354°0.7
3,154.555°0.5
10°3,051.556°0.0
11°2,937.257°0.0
12°2,812.658°0.0
13°2,678.859°0.0
14°2,537.360°0.0
15°2,389.661°0.0
16°2,237.362°0.0
17°2,082.263°0.0
18°1,925.964°0.0
19°1,770.165°0.0
20°1,616.466°0.0
21°1,466.467°0.0
22°1,321.468°0.0
23°1,182.769°0.0
24°1,051.170°0.0
25°927.671°0.0
26°812.872°0.0
27°706.973°0.0
28°610.374°0.0
29°523.075°0.0
30°444.776°0.0
31°375.377°0.0
32°314.278°0.0
33°260.979°0.0
34°215.080°0.0
35°175.781°0.0
36°142.482°0.0
37°114.583°0.0
38°91.284°0.0
39°72.185°0.0
40°56.586°0.0
41°43.987°0.0
42°33.888°0.0
43°25.889°0.0
44°19.590°0.0
45°14.6

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m8855781351511.4 m
2.5 m5664371733861.7 m
3.0 m39333117660152.1 m
3.5 m28925616373252.4 m
4.0 m22120214479342.8 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².