LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-MG02-12

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireArray - Magnetic Series, 38 degLamp / LEDIntegrated LED module
Luminous flux1,200 lmInput power12.0 W
Efficacy100.0 lm/WCCT
CRI90UGR<19
Beam angle (50% Imax)38.0°Field angle (10% Imax)62.7°
VoltageDC 48V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity2,776.6 cd
At angle0° VLuminous shapeCircular
Luminous size0 mm dia.Spacing/height (nominal)1.22

Luminous intensity (cd)

69413882082277790°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,09391.1%
0–60°1,200100.0%
0–90° (total)1,200100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m2777 luxØ0.7 m2 m694 luxØ1.4 m3 m309 luxØ2.1 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
2,776.646°8.5
2,774.947°6.3
2,767.948°4.6
2,753.749°3.3
2,731.250°2.4
2,699.551°1.7
2,658.152°1.2
2,606.853°0.8
2,545.454°0.6
2,474.155°0.4
10°2,393.356°0.0
11°2,303.757°0.0
12°2,205.958°0.0
13°2,101.059°0.0
14°1,990.060°0.0
15°1,874.261°0.0
16°1,754.862°0.0
17°1,633.163°0.0
18°1,510.564°0.0
19°1,388.365°0.0
20°1,267.866°0.0
21°1,150.167°0.0
22°1,036.468°0.0
23°927.669°0.0
24°824.470°0.0
25°727.671°0.0
26°637.572°0.0
27°554.573°0.0
28°478.774°0.0
29°410.275°0.0
30°348.876°0.0
31°294.377°0.0
32°246.478°0.0
33°204.779°0.0
34°168.680°0.0
35°137.881°0.0
36°111.782°0.0
37°89.883°0.0
38°71.684°0.0
39°56.685°0.0
40°44.386°0.0
41°34.487°0.0
42°26.588°0.0
43°20.289°0.0
44°15.390°0.0
45°11.5

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m6944531061211.4 m
2.5 m4443431363051.7 m
3.0 m30926013847122.1 m
3.5 m22720112858192.4 m
4.0 m17415911362262.8 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².