LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-FL3050300

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireMVS - Flood & Spike Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux48,000 lmInput power300.0 W
Efficacy160.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B4-U0-G0
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity123,500.0 cd
At angle0° VLuminous shapeCircular
Luminous size350 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

30875617509262512350090°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°44,83693.4%
0–60°48,000100.0%
0–90° (total)48,000100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

BUG rating B4-U0-G0

ZoneBack lmFront lm
Low 0–30°22,41822,418
Mid 30–60°1,5821,582
High 60–80°00
Very high 80–90°00
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m123500 luxØ0.6 m2 m30875 luxØ1.3 m3 m13722 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
123,500.046°169.9
123,416.947°119.9
123,062.048°83.7
122,344.249°57.8
121,205.450°39.5
119,605.751°26.7
117,520.552°17.8
114,938.253°0.0
111,860.554°0.0
108,301.055°0.0
10°104,285.356°0.0
11°99,849.657°0.0
12°95,040.158°0.0
13°89,911.059°0.0
14°84,523.760°0.0
15°78,944.461°0.0
16°73,242.362°0.0
17°67,487.863°0.0
18°61,750.064°0.0
19°56,095.465°0.0
20°50,585.766°0.0
21°45,276.467°0.0
22°40,215.868°0.0
23°35,443.669°0.0
24°30,991.170°0.0
25°26,880.271°0.0
26°23,124.372°0.0
27°19,728.273°0.0
28°16,689.274°0.0
29°13,997.875°0.0
30°11,638.776°0.0
31°9,592.277°0.0
32°7,835.378°0.0
33°6,342.579°0.0
34°5,087.380°0.0
35°4,042.981°0.0
36°3,182.982°0.0
37°2,482.283°0.0
38°1,917.284°0.0
39°1,466.685°0.0
40°1,111.086°0.0
41°833.387°0.0
42°618.888°0.0
43°454.989°0.0
44°331.090°0.0
45°238.4

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m30,87519,2483,793329211.3 m
2.5 m19,76014,8385,2799751231.6 m
3.0 m13,72211,3515,6251,6863511.9 m
3.5 m10,0828,8225,3382,1916542.3 m
4.0 m7,7196,9954,8122,4449482.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².