LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-FL3016300

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireTrabo - Flood & Spike Lights, 30 degLamp / LEDIntegrated LED module
Luminous flux45,000 lmInput power300.0 W
Efficacy150.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B4-U0-G1
Beam angle (50% Imax)30.0°Field angle (10% Imax)50.2°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity159,872.5 cd
At angle0° VLuminous shapeCircular
Luminous size737 mm dia.Spacing/height (nominal)0.94

Luminous intensity (cd)

399687993611990415987290°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°43,16395.9%
0–60°44,76699.5%
0–90° (total)45,000100.0%

Flux emitted within each downward cone. 56% of the total falls inside the rated beam angle.

BUG rating B4-U0-G1

ZoneBack lmFront lm
Low 0–30°21,58221,582
Mid 30–60°801801
High 60–80°9999
Very high 80–90°1818
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m159872 luxØ0.5 m2 m39968 luxØ1.1 m3 m17764 luxØ1.6 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
159,872.546°325.8
159,680.447°309.3
158,897.248°294.5
157,357.749°280.9
154,968.550°268.2
151,678.951°256.1
147,474.652°244.5
142,373.753°233.4
136,425.154°222.6
129,705.255°212.2
10°122,314.756°202.0
11°114,374.457°192.3
12°106,020.058°182.8
13°97,396.859°173.6
14°88,653.460°164.8
15°79,936.261°156.3
16°71,384.162°148.1
17°63,123.163°140.2
18°55,262.664°132.6
19°47,892.565°125.3
20°41,081.466°118.3
21°34,876.167°111.6
22°29,301.668°105.2
23°24,363.369°99.0
24°20,048.870°93.2
25°16,331.071°87.6
26°13,171.072°82.3
27°10,521.673°77.2
28°8,330.374°72.4
29°6,542.375°67.8
30°5,102.876°63.5
31°3,959.277°59.3
32°3,062.678°55.4
33°2,368.479°51.8
34°1,837.780°48.3
35°1,436.681°45.0
36°1,136.882°41.9
37°914.783°38.9
38°751.484°36.2
39°631.885°33.6
40°544.486°31.2
41°480.187°28.9
42°432.288°26.8
43°395.989°24.8
44°367.790°0.0
45°344.9

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m39,96820,1652,088121301.1 m
2.5 m25,58016,8643,894404511.3 m
3.0 m17,76413,4674,9399281281.6 m
3.5 m13,05110,7355,2141,4902921.9 m
4.0 m9,9928,6485,0411,9315222.1 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².