Photometric Data Sheet

CatalogueLP-ODL343524

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireStar - Wall Surface, 120 degLamp / LEDIntegrated LED module
Luminous flux2,880 lmInput power24.0 W
Efficacy120.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B1-U0-G1
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity882.7 cd
At angle0° VLuminous shapeCircular
Luminous size300 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

22144166288390°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°72525.2%
0–60°2,21376.9%
0–90° (total)2,880100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

BUG rating B1-U0-G1

ZoneBack lmFront lm
Low 0–30°363363
Mid 30–60°744744
High 60–80°283283
Very high 80–90°5050
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m883 luxØ3.5 m2 m221 luxØ6.9 m3 m98 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
882.746°666.4
882.747°652.4
882.748°637.9
882.749°623.0
882.650°607.8
882.651°592.2
882.552°576.3
882.353°560.1
882.154°543.7
881.755°527.0
10°881.356°510.1
11°880.857°493.1
12°880.158°475.9
13°879.359°458.7
14°878.360°441.4
15°877.261°424.0
16°875.962°406.8
17°874.363°389.5
18°872.564°372.4
19°870.565°355.4
20°868.266°338.6
21°865.667°322.1
22°862.768°305.8
23°859.569°289.7
24°855.970°274.0
25°852.071°258.7
26°847.772°243.7
27°843.073°229.1
28°837.974°215.0
29°832.475°201.3
30°826.576°188.1
31°820.177°175.3
32°813.378°163.1
33°806.079°151.4
34°798.280°140.2
35°789.981°129.6
36°781.182°119.5
37°771.983°109.9
38°762.184°100.8
39°751.985°92.3
40°741.186°84.2
41°729.987°76.7
42°718.188°69.7
43°705.989°63.2
44°693.290°0.0
45°680.0

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m22120015199606.9 m
2.5 m14113311183588.7 m
3.0 m989483675110.4 m
3.5 m727064544412.1 m
4.0 m555450443813.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².