LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-ODLV25

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireMoon II - Ceiling Surface Lights, 60 degLamp / LEDIntegrated LED module
Luminous flux3,000 lmInput power25.0 W
Efficacy120.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)60.0°Field angle (10% Imax)99.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity2,867.2 cd
At angle0° VLuminous shapeCircular
Luminous size66 mm dia.Spacing/height (nominal)2.34

Luminous intensity (cd)

71714342150286790°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,80260.1%
0–60°2,95698.5%
0–90° (total)3,000100.0%

Flux emitted within each downward cone. 60% of the total falls inside the rated beam angle.

Illuminance cone

1 m2867 luxØ1.2 m2 m717 luxØ2.3 m3 m319 luxØ3.5 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
2,867.246°414.7
2,866.747°374.3
2,864.248°336.8
2,859.349°302.2
2,851.550°270.2
2,840.451°240.9
2,825.852°214.0
2,807.453°189.6
2,785.154°167.3
2,758.855°147.3
10°2,728.456°129.1
11°2,693.857°112.9
12°2,655.158°98.3
13°2,612.259°85.4
14°2,565.360°73.9
15°2,514.461°63.7
16°2,459.662°54.8
17°2,401.363°46.9
18°2,339.564°40.0
19°2,274.565°34.0
20°2,206.566°28.9
21°2,135.867°24.4
22°2,062.868°20.5
23°1,987.869°17.2
24°1,911.070°14.4
25°1,832.871°12.0
26°1,753.672°9.9
27°1,673.773°8.2
28°1,593.674°6.7
29°1,513.475°5.5
30°1,433.676°4.5
31°1,354.577°3.7
32°1,276.478°3.0
33°1,199.779°2.4
34°1,124.580°1.9
35°1,051.281°1.6
36°979.982°1.2
37°910.983°1.0
38°844.584°0.8
39°780.685°0.6
40°719.586°0.5
41°661.387°0.4
42°606.088°0.3
43°553.689°0.0
44°504.390°0.0
45°458.0

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m717585306118402.3 m
2.5 m459405266137612.9 m
3.0 m319293219136733.5 m
3.5 m234220179125784.0 m
4.0 m179171146111764.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².