LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-IL82140

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireParky II - Industrial Lights, 40 degLamp / LEDIntegrated LED module
Luminous flux4,400 lmInput power40.0 W
Efficacy110.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B3-U0-G0
Beam angle (50% Imax)40.0°Field angle (10% Imax)66.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity9,207.5 cd
At angle0° VLuminous shapeCircular
Luminous size1,200 mm dia.Spacing/height (nominal)1.30

Luminous intensity (cd)

230246046906920890°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°3,89388.5%
0–60°4,400100.0%
0–90° (total)4,400100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

BUG rating B3-U0-G0

ZoneBack lmFront lm
Low 0–30°1,9471,947
Mid 30–60°253253
High 60–80°00
Very high 80–90°00
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m9208 luxØ0.7 m2 m2302 luxØ1.5 m3 m1023 luxØ2.2 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
9,207.546°55.2
9,202.747°42.1
9,182.248°31.9
9,140.549°23.9
9,074.450°17.8
8,981.351°13.1
8,859.452°9.6
8,707.953°7.0
8,526.254°5.0
8,314.855°3.6
10°8,074.456°2.5
11°7,806.457°1.8
12°7,512.858°1.2
13°7,196.059°0.0
14°6,858.860°0.0
15°6,504.661°0.0
16°6,136.762°0.0
17°5,758.963°0.0
18°5,374.964°0.0
19°4,988.665°0.0
20°4,603.866°0.0
21°4,223.967°0.0
22°3,852.568°0.0
23°3,492.569°0.0
24°3,146.870°0.0
25°2,817.571°0.0
26°2,506.772°0.0
27°2,215.973°0.0
28°1,945.974°0.0
29°1,697.575°0.0
30°1,470.876°0.0
31°1,265.777°0.0
32°1,081.778°0.0
33°918.079°0.0
34°773.580°0.0
35°647.181°0.0
36°537.482°0.0
37°443.083°0.0
38°362.584°0.0
39°294.485°0.0
40°237.386°0.0
41°189.887°0.0
42°150.688°0.0
43°118.689°0.0
44°92.790°0.0
45°71.8

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m2,3021,5634195861.5 m
2.5 m1,4731,164503128241.8 m
3.0 m1,023875494186522.2 m
3.5 m752673447217822.5 m
4.0 m5755303912251052.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².