LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-IL2950150

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireAndres - Industrial Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux19,500 lmInput power150.0 W
Efficacy130.0 lm/WCCT
CRI>90BUG rating (TM-15-11)B4-U0-G0
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC100~277V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity50,171.9 cd
At angle0° VLuminous shapeCircular
Luminous size300 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

1254325086376295017290°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°18,21593.4%
0–60°19,500100.0%
0–90° (total)19,500100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

BUG rating B4-U0-G0

ZoneBack lmFront lm
Low 0–30°9,1079,107
Mid 30–60°643643
High 60–80°00
Very high 80–90°00
Uplight 90–100° / 100–180°0 / 0

Backlight, Uplight and Glare classes from the zone lumens, IES TM-15-11 limits. Calculated from this distribution.

Illuminance cone

1 m50172 luxØ0.6 m2 m12543 luxØ1.3 m3 m5575 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
50,171.946°69.0
50,138.147°48.7
49,993.948°34.0
49,702.349°23.5
49,239.750°16.0
48,589.851°10.8
47,742.752°7.2
46,693.653°0.0
45,443.354°0.0
43,997.355°0.0
10°42,365.956°0.0
11°40,563.957°0.0
12°38,610.058°0.0
13°36,526.459°0.0
14°34,337.860°0.0
15°32,071.261°0.0
16°29,754.762°0.0
17°27,416.963°0.0
18°25,085.964°0.0
19°22,788.865°0.0
20°20,550.466°0.0
21°18,393.667°0.0
22°16,337.768°0.0
23°14,399.069°0.0
24°12,590.170°0.0
25°10,920.171°0.0
26°9,394.272°0.0
27°8,014.673°0.0
28°6,780.074°0.0
29°5,686.675°0.0
30°4,728.276°0.0
31°3,896.977°0.0
32°3,183.178°0.0
33°2,576.779°0.0
34°2,066.780°0.0
35°1,642.481°0.0
36°1,293.082°0.0
37°1,008.483°0.0
38°778.984°0.0
39°595.885°0.0
40°451.386°0.0
41°338.587°0.0
42°251.488°0.0
43°184.889°0.0
44°134.590°0.0
45°96.9

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m12,5437,8191,54113491.3 m
2.5 m8,0286,0282,145396501.6 m
3.0 m5,5754,6112,2856851421.9 m
3.5 m4,0963,5842,1688902662.3 m
4.0 m3,1362,8421,9559933852.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².