LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-PNL215055

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireHero II - Panel Lights, 120 degLamp / LEDIntegrated LED module
Luminous flux5,500 lmInput power55.0 W
Efficacy100.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity1,685.7 cd
At angle0° VLuminous shapeCircular
Luminous size1,195 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

4218431264168690°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,38525.2%
0–60°4,22776.9%
0–90° (total)5,500100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

Illuminance cone

1 m1686 luxØ3.5 m2 m421 luxØ6.9 m3 m187 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
1,685.746°1,272.7
1,685.747°1,245.8
1,685.748°1,218.2
1,685.749°1,189.8
1,685.650°1,160.8
1,685.551°1,131.0
1,685.352°1,100.6
1,684.953°1,069.7
1,684.554°1,038.3
1,683.955°1,006.4
10°1,683.156°974.2
11°1,682.057°941.7
12°1,680.858°908.9
13°1,679.259°875.9
14°1,677.460°842.9
15°1,675.261°809.8
16°1,672.662°776.8
17°1,669.763°743.9
18°1,666.264°711.2
19°1,662.465°678.8
20°1,657.966°646.7
21°1,653.067°615.1
22°1,647.568°583.9
23°1,641.369°553.3
24°1,634.570°523.3
25°1,627.071°494.0
26°1,618.872°465.4
27°1,609.973°437.5
28°1,600.274°410.5
29°1,589.775°384.4
30°1,578.476°359.2
31°1,566.277°334.9
32°1,553.178°311.5
33°1,539.279°289.2
34°1,524.380°267.8
35°1,508.581°247.5
36°1,491.882°228.1
37°1,474.183°209.8
38°1,455.584°192.5
39°1,435.985°176.2
40°1,415.386°160.9
41°1,393.887°146.5
42°1,371.488°133.1
43°1,348.189°120.7
44°1,323.890°0.0
45°1,298.7

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m4213832891891156.9 m
2.5 m2702542111581108.7 m
3.0 m1871801581289810.4 m
3.5 m1381331211048412.1 m
4.0 m10510396857213.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².