LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-PNL214536

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireJet II - Panel Lights, 120 degLamp / LEDIntegrated LED module
Luminous flux3,650 lmInput power36.0 W
Efficacy101.4 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity1,118.7 cd
At angle0° VLuminous shapeCircular
Luminous size1,196 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

280559839111990°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°91925.2%
0–60°2,80576.9%
0–90° (total)3,650100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

Illuminance cone

1 m1119 luxØ3.5 m2 m280 luxØ6.9 m3 m124 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
1,118.746°844.6
1,118.747°826.8
1,118.748°808.5
1,118.749°789.6
1,118.650°770.3
1,118.551°750.6
1,118.452°730.4
1,118.253°709.9
1,117.954°689.1
1,117.555°667.9
10°1,116.956°646.5
11°1,116.357°624.9
12°1,115.458°603.2
13°1,114.459°581.3
14°1,113.260°559.4
15°1,111.761°537.4
16°1,110.062°515.5
17°1,108.163°493.7
18°1,105.864°472.0
19°1,103.265°450.5
20°1,100.366°429.2
21°1,097.067°408.2
22°1,093.368°387.5
23°1,089.269°367.2
24°1,084.770°347.3
25°1,079.871°327.8
26°1,074.372°308.8
27°1,068.473°290.4
28°1,062.074°272.4
29°1,055.075°255.1
30°1,047.576°238.4
31°1,039.477°222.2
32°1,030.778°206.7
33°1,021.479°191.9
34°1,011.680°177.7
35°1,001.181°164.2
36°990.082°151.4
37°978.383°139.2
38°965.984°127.8
39°952.985°116.9
40°939.386°106.8
41°925.087°97.3
42°910.188°88.4
43°894.689°80.1
44°878.590°0.0
45°861.8

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m280254192125766.9 m
2.5 m179168140105738.7 m
3.0 m124119105856510.4 m
3.5 m918981695612.1 m
4.0 m706864564813.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².