LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-PNL213532

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireJet - Panel Lights, 120 degLamp / LEDIntegrated LED module
Luminous flux3,390 lmInput power32.0 W
Efficacy105.9 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)120.0°Field angle (10% Imax)171.0°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity1,039.0 cd
At angle0° VLuminous shapeCircular
Luminous size596 mm dia.Spacing/height (nominal)11.34

Luminous intensity (cd)

260520779103990°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°85425.2%
0–60°2,60576.9%
0–90° (total)3,390100.0%

Flux emitted within each downward cone. 77% of the total falls inside the rated beam angle.

Illuminance cone

1 m1039 luxØ3.5 m2 m260 luxØ6.9 m3 m115 luxØ10.4 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
1,039.046°784.4
1,039.047°767.9
1,039.048°750.9
1,039.049°733.4
1,038.950°715.4
1,038.951°697.1
1,038.752°678.4
1,038.553°659.3
1,038.254°640.0
1,037.955°620.3
10°1,037.456°600.5
11°1,036.757°580.4
12°1,036.058°560.2
13°1,035.059°539.9
14°1,033.960°519.5
15°1,032.561°499.1
16°1,031.062°478.8
17°1,029.163°458.5
18°1,027.064°438.4
19°1,024.665°418.4
20°1,021.966°398.6
21°1,018.867°379.1
22°1,015.468°359.9
23°1,011.669°341.0
24°1,007.570°322.5
25°1,002.871°304.5
26°997.872°286.8
27°992.373°269.7
28°986.374°253.0
29°979.875°236.9
30°972.876°221.4
31°965.377°206.4
32°957.378°192.0
33°948.779°178.2
34°939.580°165.1
35°929.881°152.5
36°919.582°140.6
37°908.683°129.3
38°897.184°118.7
39°885.085°108.6
40°872.486°99.2
41°859.187°90.3
42°845.388°82.1
43°830.989°74.4
44°815.990°0.0
45°800.5

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m260236178116716.9 m
2.5 m16615613097688.7 m
3.0 m11511197796010.4 m
3.5 m858275645212.1 m
4.0 m656359524413.9 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².