Photometric Data Sheet

CatalogueLP-PL258020

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireGHALA - Suspended & Pendant, 90 degLamp / LEDIntegrated LED module
Luminous flux2,800 lmInput power20.0 W
Efficacy140.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)90.0°Field angle (10% Imax)130.2°
Voltage85-265V 50/60Hz

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity1,381.6 cd
At angle0° VLuminous shapeCircular
Luminous size500 mm dia.Spacing/height (nominal)4.30

Luminous intensity (cd)

3456911036138290°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,09038.9%
0–60°2,58292.2%
0–90° (total)2,800100.0%

Flux emitted within each downward cone. 72% of the total falls inside the rated beam angle.

Illuminance cone

1 m1382 luxØ2.0 m2 m345 luxØ4.0 m3 m154 luxØ6.0 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
1,381.646°655.2
1,381.547°619.9
1,381.548°584.8
1,381.449°550.1
1,381.250°516.1
1,380.851°482.7
1,380.352°450.2
1,379.553°418.6
1,378.454°388.0
1,376.955°358.6
10°1,375.056°330.5
11°1,372.757°303.6
12°1,369.858°278.1
13°1,366.359°254.0
14°1,362.260°231.3
15°1,357.361°210.0
16°1,351.662°190.2
17°1,345.163°171.8
18°1,337.664°154.9
19°1,329.165°139.3
20°1,319.666°125.1
21°1,309.067°112.1
22°1,297.268°100.4
23°1,284.269°89.8
24°1,269.970°80.4
25°1,254.371°71.9
26°1,237.572°64.4
27°1,219.373°57.8
28°1,199.774°51.9
29°1,178.775°46.8
30°1,156.476°42.4
31°1,132.777°38.5
32°1,107.778°35.1
33°1,081.479°32.2
34°1,053.880°29.6
35°1,025.181°27.5
36°995.282°25.6
37°964.283°23.9
38°932.384°22.5
39°899.585°21.3
40°865.986°20.2
41°831.787°19.3
42°796.988°18.4
43°761.889°17.7
44°726.390°0.0
45°690.8

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m345311220124614.0 m
2.5 m221207166114695.0 m
3.0 m15414712798686.0 m
3.5 m1131099881627.0 m
4.0 m86847867558.0 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².