Photometric Data Sheet

CatalogueLP-CL244110

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireCYLINDRO - Suspended & Pendant, 36 degLamp / LEDIntegrated LED module
Luminous flux1,400 lmInput power10.0 W
Efficacy140.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity3,602.1 cd
At angle0° VLuminous shapeCircular
Luminous size75 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

90118012702360290°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,30893.4%
0–60°1,400100.0%
0–90° (total)1,400100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m3602 luxØ0.6 m2 m901 luxØ1.3 m3 m400 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
3,602.146°5.0
3,599.747°3.5
3,589.348°2.4
3,568.449°1.7
3,535.250°1.2
3,488.551°0.8
3,427.752°0.5
3,352.453°0.0
3,262.654°0.0
3,158.855°0.0
10°3,041.756°0.0
11°2,912.357°0.0
12°2,772.058°0.0
13°2,622.459°0.0
14°2,465.360°0.0
15°2,302.561°0.0
16°2,136.262°0.0
17°1,968.463°0.0
18°1,801.064°0.0
19°1,636.165°0.0
20°1,475.466°0.0
21°1,320.667°0.0
22°1,173.068°0.0
23°1,033.869°0.0
24°903.970°0.0
25°784.071°0.0
26°674.572°0.0
27°575.473°0.0
28°486.874°0.0
29°408.375°0.0
30°339.576°0.0
31°279.877°0.0
32°228.578°0.0
33°185.079°0.0
34°148.480°0.0
35°117.981°0.0
36°92.882°0.0
37°72.483°0.0
38°55.984°0.0
39°42.885°0.0
40°32.486°0.0
41°24.387°0.0
42°18.088°0.0
43°13.389°0.0
44°9.790°0.0
45°7.0

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m9015611111011.3 m
2.5 m5764331542841.6 m
3.0 m40033116449101.9 m
3.5 m29425715664192.3 m
4.0 m22520414071282.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².