LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-DL181630

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireShine - Down Lights, 38 degLamp / LEDIntegrated LED module
Luminous flux3,600 lmInput power30.0 W
Efficacy120.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)38.0°Field angle (10% Imax)62.7°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity8,329.7 cd
At angle0° VLuminous shapeCircular
Luminous size140 mm dia.Spacing/height (nominal)1.22

Luminous intensity (cd)

208241656247833090°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°3,27991.1%
0–60°3,600100.0%
0–90° (total)3,600100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m8330 luxØ0.7 m2 m2082 luxØ1.4 m3 m926 luxØ2.1 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
8,329.746°25.6
8,324.847°18.8
8,303.848°13.7
8,261.249°9.9
8,193.650°7.1
8,098.651°5.0
7,974.452°3.5
7,820.353°2.5
7,636.154°1.7
7,422.355°1.2
10°7,180.056°0.0
11°6,911.157°0.0
12°6,617.858°0.0
13°6,303.159°0.0
14°5,970.160°0.0
15°5,622.661°0.0
16°5,264.362°0.0
17°4,899.263°0.0
18°4,531.464°0.0
19°4,164.965°0.0
20°3,803.366°0.0
21°3,450.467°0.0
22°3,109.368°0.0
23°2,782.869°0.0
24°2,473.370°0.0
25°2,182.771°0.0
26°1,912.472°0.0
27°1,663.473°0.0
28°1,436.174°0.0
29°1,230.575°0.0
30°1,046.476°0.0
31°882.977°0.0
32°739.278°0.0
33°614.079°0.0
34°505.980°0.0
35°413.481°0.0
36°335.182°0.0
37°269.383°0.0
38°214.784°0.0
39°169.785°0.0
40°132.986°0.0
41°103.387°0.0
42°79.588°0.0
43°60.789°0.0
44°45.990°0.0
45°34.4

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m2,0821,3603173631.4 m
2.5 m1,3331,02940790141.7 m
3.0 m926780415141352.1 m
3.5 m680603383173582.4 m
4.0 m521476340185792.8 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².