LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-SL172218

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireCova - Down Lights, 38 degLamp / LEDIntegrated LED module
Luminous flux2,070 lmInput power18.0 W
Efficacy115.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)38.0°Field angle (10% Imax)62.7°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity4,789.6 cd
At angle0° VLuminous shapeCircular
Luminous size145 mm dia.Spacing/height (nominal)1.22

Luminous intensity (cd)

119723953592479090°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°1,88591.1%
0–60°2,070100.0%
0–90° (total)2,070100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m4790 luxØ0.7 m2 m1197 luxØ1.4 m3 m532 luxØ2.1 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
4,789.646°14.7
4,786.847°10.8
4,774.748°7.9
4,750.249°5.7
4,711.350°4.1
4,656.751°2.9
4,585.352°2.0
4,496.753°1.4
4,390.854°1.0
4,267.855°0.7
10°4,128.556°0.0
11°3,973.957°0.0
12°3,805.258°0.0
13°3,624.359°0.0
14°3,432.860°0.0
15°3,233.061°0.0
16°3,027.062°0.0
17°2,817.063°0.0
18°2,605.664°0.0
19°2,394.865°0.0
20°2,186.966°0.0
21°1,984.067°0.0
22°1,787.868°0.0
23°1,600.169°0.0
24°1,422.170°0.0
25°1,255.071°0.0
26°1,099.672°0.0
27°956.473°0.0
28°825.874°0.0
29°707.675°0.0
30°601.776°0.0
31°507.777°0.0
32°425.078°0.0
33°353.079°0.0
34°290.980°0.0
35°237.781°0.0
36°192.782°0.0
37°154.983°0.0
38°123.484°0.0
39°97.685°0.0
40°76.486°0.0
41°59.487°0.0
42°45.788°0.0
43°34.989°0.0
44°26.490°0.0
45°19.8

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m1,1977821822021.4 m
2.5 m7665922345281.7 m
3.0 m53244823881202.1 m
3.5 m39134622099342.4 m
4.0 m299274195106462.8 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².