LIGHT PLUS UK

Photometric Data Sheet

CatalogueLP-DL908309

Calculated photometric data — nominal values derived from a distribution model. Not LM-79 laboratory tested.

LuminaireKINGSTON - Spot Lights, 36 degLamp / LEDIntegrated LED module
Luminous flux990 lmInput power9.0 W
Efficacy110.0 lm/WCCT
CRI>90UGR<19
Beam angle (50% Imax)36.0°Field angle (10% Imax)59.4°
VoltageAC220~240V

Goniometry summary

DistributionDirect, rotationally symmetricMaximum intensity2,547.2 cd
At angle0° VLuminous shapeCircular
Luminous size62 mm dia.Spacing/height (nominal)1.14

Luminous intensity (cd)

63712741910254790°90°

Polar distribution, rotationally symmetric. 0° is straight down.

Zonal lumen summary

ZoneLumens% of total
0–30°92593.4%
0–60°990100.0%
0–90° (total)990100.0%

Flux emitted within each downward cone. 59% of the total falls inside the rated beam angle.

Illuminance cone

1 m2547 luxØ0.6 m2 m637 luxØ1.3 m3 m283 luxØ1.9 m

Centre-beam illuminance and beam diameter on a surface directly below.

Intensity table

γcdγcd
2,547.246°3.5
2,545.547°2.5
2,538.248°1.7
2,523.349°1.2
2,499.950°0.8
2,466.951°0.6
2,423.952°0.4
2,370.653°0.0
2,307.154°0.0
2,233.755°0.0
10°2,150.956°0.0
11°2,059.457°0.0
12°1,960.258°0.0
13°1,854.459°0.0
14°1,743.360°0.0
15°1,628.261°0.0
16°1,510.662°0.0
17°1,391.963°0.0
18°1,273.664°0.0
19°1,157.065°0.0
20°1,043.366°0.0
21°933.867°0.0
22°829.568°0.0
23°731.069°0.0
24°639.270°0.0
25°554.471°0.0
26°476.972°0.0
27°406.973°0.0
28°344.274°0.0
29°288.775°0.0
30°240.076°0.0
31°197.877°0.0
32°161.678°0.0
33°130.879°0.0
34°104.980°0.0
35°83.481°0.0
36°65.682°0.0
37°51.283°0.0
38°39.584°0.0
39°30.285°0.0
40°22.986°0.0
41°17.287°0.0
42°12.888°0.0
43°9.489°0.0
44°6.890°0.0
45°4.9

Candela at each vertical angle, C0-C180 plane.

Floor illuminance & spacing (lux)

Mounting heightcentre0.5 m1.0 m1.5 m2.0 mBeam Ø
2.0 m63739778701.3 m
2.5 m4083061092031.6 m
3.0 m2832341163571.9 m
3.5 m20818211045132.3 m
4.0 m1591449950202.6 m

Horizontal illuminance directly below the fitting (centre) and at each radial offset, for a single fitting. Use it to judge spacing for uniform light. Point-source projection, E = I·cosθ / D².